Model 410 Series
Syringe Pumps
Users Manual
Publication 5605-00
1-REV
-D
Przeglądanie stron 0
1 2 3 4 5 6 ... 37 38

Podsumowanie treści

Strona 1 - User’s Manual

Model 410 SeriesSyringe PumpsUser’s ManualPublication 5605-001-REV-D

Strona 2

8KDS Model 410 Series Syringe PumpsOperating Instructions (Continued)SYRINGE LOADING(1) “T” Knob for securingthe adjustable Clamp Rod(7) Plunger Knob(

Strona 3 - Contents

9KDS Model 410 Series Syringe Pumps(1 & 2) ShoulderScrew (2 places) for tightening the“V” Clamp(3 & 4)“T” Knob (2 places) foradjusting theFlan

Strona 4

10KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating Instructions (Continued)SYRINGE LOADING (Continued)5. Place the syring

Strona 5 - Specifications

11KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating Instructions (Continued)UNITS SETTINGprompt: Vol.: 00.00 ml <The un

Strona 6 - General Safety Summary

12KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating Instructions (Continued)CHANGE OR REVIEW VOLUME SETTING WHILE RUNNINGW

Strona 7 - Features

13KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating Instructions (Continued)MANUAL STALL SETTING AND MICROLITER SYRINGES(N

Strona 8 - Features (continued)

14KDS Model 410 Series Syringe Pumps13KDS Model 410 Series Syringe PumpsOperating Instructions (Continued)CLEARING A STALL CONDITIONShould a stall occ

Strona 9 - Operating Instructions

15KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating Instructions (Continued)RS232 COMMANDSRS232 is used for remote compute

Strona 10

16KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating Instructions (Continued)RS232 COMMANDS (continued)Prompts >running

Strona 11

17KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating Instructions (Continued)RS232 COMMANDS (continued)ratei nnnnn u/uSets

Strona 12

EU Directives WEEE and RoHSTo Our Valued Customers:We are committed to being a good corporate citizen. As part of that commitment,we strive to maintai

Strona 13

18KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating Instructions (Continued)RS232 COMMANDS (continued)error? Errors 8 - 15

Strona 14

19KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsProgrammable Option– General InformationKEYPAD PROGRAMMABLE PUMPSThe "progr

Strona 15

20KDS Model 410 Series Syringe PumpsProgrammable Option–FeaturesPARAMETERS WHICH CAN BE PROGRAMMED IN EACH STEPTime durationInfuse or withdrawStart fl

Strona 16

21KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsProgrammable Option– Menu OperationAfter selecting MODE and then PROGRAM the dis

Strona 17

22KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsProgrammable Option– Menu Operation (Continued)8) Loop (Continued)b) LOOP COUNTA

Strona 18

23KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsProgrammable Option– Running The ProgramRun The Run key starts the program; the

Strona 19

24KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsProgrammable Option– RS232 Commands and ResponsesAll commands and responses in s

Strona 20

25KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsProgrammable Option– RS232 Commands and Responses(Continued)mode prgmsets pump i

Strona 21

KDS Model 410 Series Syringe Pumps26Programmable Option– RS232 Commands and Responses(Continued)timeleft?queries time remaining in active stepresponse

Strona 22 - Programmable Option–Features

27KDS Model 410 Series Syringe PumpsProgrammable Option– RS232 Commands and Responses(Continued)PROGRAM EXAMPLESyringe selected, 4.70 mm diameterRS232

Strona 23

1KDS Model 410 Series Syringe PumpsContentsSpecifications...

Strona 24

28KDS Model 410 Series Syringe PumpsRS232 COMMANDSRS232 Format8 data bitsNo parity1 stop (can use 2 stops)Pump uses simple three wire communications -

Strona 25

29KDS Model 410 Series Syringe Pumps549876321TTL SpecificationsPin3 Vss , ground ref.1,6 Controllable output with Programmable models could be used fo

Strona 26

30KDS Model 410 Series Syringe PumpsMaintenanceMaintenance is required only for the moving mechanical parts, which should be kept cleanand lubricated.

Strona 27

31KDS Model 410 Series Syringe Pumps(1) "Air-Tite "All Plastic1cc 4.70 mm2.5 9.705.0 12.4810 15.8920 20.0030 22.5050 28.90(2) Becton Dickins

Strona 28

32KDS Model 410 Series Syringe Pumps(1) "Air-Tite "All Plastic1cc 4.70 mm2.5 9.705.0 12.4810 15.8920 20.0030 22.5050 28.90(2) Becton Dickins

Strona 29

33KDS Model 410 Series Syringe PumpsStandard Minimum and Maximum Flow RatesSyringe size Diameter* Minimum Maximum10 µl 0.46 mm 0.001 µl/hr 21.10 µl/mi

Strona 30 - RS232 COMMANDS

34KDS Model 410 Series Syringe PumpsJapanese Minimum and Maximum Flow Rates(Available in Japanese Models)Syringe size Diameter* Minimum Maximum10 µl 0

Strona 31 - TTL Specifications

35KDS Model 410 Series Syringe PumpsLimited WarrantyKD Scientific Inc. warrants to the first consumer purchaser, for a period of one year from thedate

Strona 32 - Maintenance

EU Directives WEEE and RoHSTo Our Valued Customers:We are committed to being a good corporate citizen. As part of that commitment,we strive to maintai

Strona 33

2KDS Model 410 Series Syringe PumpsJapanese Table of Syringe Diameters ...3

Strona 34

3KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsSpecificationsModel 410 SeriesSyringe Size 10 microliter to 140 milliliterElectri

Strona 35

4KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsGeneral Safety SummaryPlease read the following safety precautions to ensure prop

Strona 36

5KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsGeneral DescriptionThis manual applies to the KDS410 series infusion/withdrawal p

Strona 37 - Limited Warranty

6KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsFeatures (continued)4) MODES OF OPERATIONInfusionRate and volume settings: pump i

Strona 38

7KDS Model 410 Series Syringe PumpsKDS Model 410 Series Syringe PumpsOperating InstructionsPOWER SWITCHThe power switch is located in the middle of th